DIGITUS four-fan roof module, 9.2 m³/min and 552 m³/h free-blowing, 60–65 dB, 13.8 W

The best-measured cooling unit in this hub and the only one that says what its airflow figure assumes: 552 cubic metres an hour, free-blowing, which is not the same as inside a closed cabinet.

DIGITUS black four-fan roof cooling module for a network cabinet

DIGITUS four-fan roof module, 9.2 m³/min and 552 m³/h free-blowing, 60–65 dB, 13.8 W

The best-measured cooling unit in this hub and the only one that says what its airflow figure assumes: 552 cubic metres an hour, free-blowing, which is not the same as inside a closed cabinet.

Fan count
Four — stated in the title and in the third bullet, which gives the count alongside the two airflow figures
Fan size
Not published on the listing — no diameter and no frame dimension appears in any bullet. The third gives the airflow and the count and no dimension for either fan
Stated airflow
9.2 m³/min, and 552 m³/h given as the free-blowing volume flow — both stated in the third bullet. The words free-blowing are the maker’s own and they qualify the figure: it is the throughput with nothing resisting it, rather than inside a closed cabinet
Airflow unit
Cubic metres, published twice — per minute and per hour. The other measured unit on this shelf publishes cubic feet per minute, so the two cannot be compared without converting one of them
Stated noise level
60 to 65 dB with four fans fitted — stated in the fourth bullet, which ties the figure explicitly to the number of fans running. The measuring distance is not published on the listing. It is the loudest figure on this shelf
Roof or rack-mount format
Roof — stated in the title and in the second bullet, which describes a roof fan module and says matching holes are present in the cabinet roof of the ranges named in the first
Rack units occupied
None stated, and a roof module consumes none: the second bullet places it in the cabinet roof rather than on the profile rails. No rack unit figure appears on the page
Airflow direction
Not published on the listing — nothing says which way the fans push and nothing says whether they can be turned in their frame. The second bullet places the module in the roof and stops there
Thermostat or speed control
A thermostat covering 0 °C to +35 °C — stated in the fourth bullet. It is one of two threshold ranges published on this shelf and the narrower of the two
Power connection
A rated power of 13.8 W, with an input of AC 50 Hz at 240 V, AC 60 Hz at 220 V or DC 48 V — all stated in the fifth bullet. No lead, inlet or plug type is published
Amazon reference
B00DNRPFQG (same reference on 6 Amazon marketplaces)
EAN
4016032332855
  • The only listing here that says what its airflow figure assumes, by naming it free-blowing
  • Publishes the airflow in two units, so no conversion is needed to read it
  • Sixty to sixty-five decibels, the loudest figure published in this hub

Best for: A DIGITUS cabinet of one of the named ranges, in a room where nobody has to sit next to sixty decibels.

≈ 92 €
Check price on Amazon

Specifications

Fan count
Four — stated in the title and in the third bullet, which gives the count alongside the two airflow figures
Fan size
Not published on the listing — no diameter and no frame dimension appears in any bullet. The third gives the airflow and the count and no dimension for either fan
Stated airflow
9.2 m³/min, and 552 m³/h given as the free-blowing volume flow — both stated in the third bullet. The words free-blowing are the maker’s own and they qualify the figure: it is the throughput with nothing resisting it, rather than inside a closed cabinet
Airflow unit
Cubic metres, published twice — per minute and per hour. The other measured unit on this shelf publishes cubic feet per minute, so the two cannot be compared without converting one of them
Stated noise level
60 to 65 dB with four fans fitted — stated in the fourth bullet, which ties the figure explicitly to the number of fans running. The measuring distance is not published on the listing. It is the loudest figure on this shelf
Roof or rack-mount format
Roof — stated in the title and in the second bullet, which describes a roof fan module and says matching holes are present in the cabinet roof of the ranges named in the first
Rack units occupied
None stated, and a roof module consumes none: the second bullet places it in the cabinet roof rather than on the profile rails. No rack unit figure appears on the page
Airflow direction
Not published on the listing — nothing says which way the fans push and nothing says whether they can be turned in their frame. The second bullet places the module in the roof and stops there
Thermostat or speed control
A thermostat covering 0 °C to +35 °C — stated in the fourth bullet. It is one of two threshold ranges published on this shelf and the narrower of the two
Power connection
A rated power of 13.8 W, with an input of AC 50 Hz at 240 V, AC 60 Hz at 220 V or DC 48 V — all stated in the fifth bullet. No lead, inlet or plug type is published
Amazon reference
B00DNRPFQG (same reference on 6 Amazon marketplaces)
EAN
4016032332855

On the listing

A roof fan module for DIGITUS Unique and Unique Light network cabinets and Unique Server-N server cabinets, with matching holes present in the cabinet roof, in black; four fans, an airflow of 9.2 m³/min and a free-blowing volume flow of 552 m³/h; a thermostat covering 0 °C to +35 °C and a noise level of 60 to 65 dB with four fans fitted; and a rated power of 13.8 W with an input of AC 50 Hz at 240 V, AC 60 Hz at 220 V or DC 48 V.

Free-blowing, which is the honest word

Two words in the third bullet make this the best-documented cooling unit in this hub.

Five hundred and fifty-two cubic metres an hour, free-blowing.

A fan tested with nothing in front of it moves more air than the same fan bolted into the roof of a closed cabinet, because a cabinet is a series of obstructions — entries, vents, equipment, cable bundles — and each of them is resistance the fan has to push against. The figure that results in a real installation is lower, and how much lower depends on the cabinet rather than on the fan.

Every fan specification anywhere has this problem. What is unusual is a listing that says so. The other measured unit on this shelf publishes a range and never qualifies it; the five remaining listings publish no airflow at all.

Reading it correctly does not make the number less useful. It makes it comparable, which is the whole point.

Two units for one figure

The same bullet publishes cubic metres per minute and cubic metres per hour: 9.2 and 552.

They are the same measurement multiplied by sixty, which sounds redundant and is not. Makers use both, and a buyer holding two datasheets in different units has to convert one of them before the comparison means anything. Publishing both removes the step, and it removes the most common error on this shelf.

The one comparison that still needs work is with the other measured unit here, which publishes cubic feet per minute. Metric and imperial are not the same scale, and the numbers look nothing like each other.

Sixty to sixty-five decibels

This is the loudest figure in this hub, and it is published rather than hidden.

The fourth bullet ties it explicitly to the condition producing it: 60 to 65 dB with four fans fitted. That qualification is the same instinct as the free-blowing one — a number given with the circumstance that produced it.

What it means in practice is that this is not a unit for a cabinet in a study or a bedroom wall. It is a unit for a plant room, a garage, a cupboard behind a closed door. The thermostat helps, because 0 to +35 °C means the fans are not running when the cabinet is cool, but when they run they will be heard.

No measuring distance is published, which is the gap both noise figures on this shelf share.

Watts, and a DC input

The fifth bullet publishes a rated power of 13.8 W and three input options, one of them 48 V DC.

The wattage is the figure nobody else on this shelf gives, and it answers a question about running a unit continuously that airflow cannot. The DC option is unusual in a domestic context and entirely ordinary in a rack that has a 48 V supply in it already.

The cabinets it is drilled for

The compatibility is the constraint, and the first two bullets are clear about it: Unique and Unique Light network cabinets, Unique Server-N server cabinets, matching holes present in their roofs.

A roof module goes through a cut-out. If the cut-out is not there or is a different shape, the module has nowhere to sit. This page describes the alignment for the ranges it names and says nothing about anything else, which is a limit rather than a fault — but it is the first thing to check.

Before ordering

Confirm the cabinet is one of the named ranges, or measure the roof aperture and ask. Read the airflow as a free-blowing figure and expect less in a closed cabinet. And listen to the room before committing: 60 to 65 dB is the loudest thing on this shelf, and it is published for a reason.

Availability

Priced from 92 € to 145 € across the German, French, Italian and Spanish Amazon stores the day this page was checked.

It is stocked on the British Amazon store as well, in that country’s own currency. The range above leaves those out: it counts euro stores and no others.

In the American Amazon catalogue with no live offer against it: the reference exists, nobody is filling it.